Accessories
Our original accessories provide you with high-quality items to optimise the performance of your Huber temperature control unit. You will find the right item in our extensive range: From adapters & distributors to bath vessels and regulators to thermofluids.
The model and category selection below will help you quickly find the product you need.

Holder for immersion coolers TC45/-E,TC50/-E, TC100/-E
for mounting on bath

Connection cable for Pilot ONE for using the controller as remote control (without RS232)
Length: 3m
Using #16160 as remote control does not allow communication via RS232. If required, please use #56196.

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 100 cm
Connection: G1/2
Max. pressure at 20°C: 10 bar
Internal diameter: 15 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 150 cm
Connection: G1/2
Max. pressure at 20°C: 10 bar
Internal diameter: 15 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 200 cm
Connection: G1/2
Max. pressure at 20°C: 10 bar
Internal diameter: 15 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 100 cm
Connection: G3/4
Max. pressure at 20°C: 10 bar
Internal diameter: 20 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 150 cm
Connection: G3/4
Max. Pressure at 20°C: 10 bar
Internal diameter: 20 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 200 cm
Connection: G3/4
Max. pressure at 20°C: 10 bar
Internal diameter: 20 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 100 cm
Connection: G1
Max. pressure at 20°C: 10 bar
Internal diameter: 25 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 150 cm
Connection: G1
Max. pressure at 20°C: 10 bar
Internal diameter: 25 mm

Material: HDPE with Braiding
Temperature range: -20°C...90°C
Length: 200 cm
Connection: G1
Max. pressure at 20°C: 10 bar
Internal diameter: 25 mm

Bath opening (W x D): 480 x 180 mm
Bath depth: 312 mm
Bath volume: 30 liters
Dimensions (W x D x H): 500 x 200 x 322 mm

Thickness: 13 mm
Internal diameter: 22 mm
Sold per meter

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 100 cm
Connection: G1 1/4
Max. pressure at 20°C: 6 bar
Internal diameter: 32 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 150 cm
Connection: G1 1/4
Max. pressure at 20°C: 6 bar
Internal diameter: 32 mm

Material: HDPE with braiding
Temperature range: -20°C...90°C
Length: 200 cm
Connection: G1 1/4
Max. pressure at 20°C: 6 bar
Internal diameter: 32 mm

Thickness: 13 mm
Internal diameter: 28 mm
Sold per meter








Pump adapter cpl.
for KISS E, CC-E and with baths 106A to 118A
incl. hose connectors NW12

Pump adapter cpl.
for KISS E, CC-E and baths 208B to 225B and K12 to K25
incl. hose connectors NW12



Bath opening (W x D): 303 x 342 mm
Bath depth: 150 mm
Bath volume: 12 liters
Dimensions (W x D x H): 333 x 358 x 166 mm

Bath opening (W x D): 303 x 502 mm
Bath depth: 150 mm
Bath volume: 18 liters
Dimensions (W x D x H): 333 x 518 x 166 mm

Bath opening (W x D): 130 x 290 mm
Bath depth: 150 mm
Bath volume: 6 liters
Dimensions (W x D x H): 142 x 305 x 161 mm

Bath opening (W x D): 130 x 390 mm
Bath depth: 150 mm
Bath volume: 8 liters
Dimensions (W x D x H): 142 x 405 x 161 mm

Bath opening (W x D): 130 x 490 mm
Bath depth: 150 mm
Bath volume: 10 liters
Dimensions (W x D x H): 142 x 505 x 161 mm




Drain tap suitable for canisters with heat transfer fluids.
For easy filling of the temperature control unit with heat transfer fluid directly from the canister.
With drain valve, 23 mm, ventilated


Temperature range: -20°C...180°C
Length: variable
Max. pressure at 20°C: low pressure
Internal diameter: 12 mm
Material: FKM
Sold per meter


Temperature sensor Pt100, M38x1,5, for fluid outlet or return




Temperature range: -10°C ... +180°C (max. 6 bar at +180°C)



M24x1,5 female thread to M24x1,5 male thread

Temperature range: -10°C ... 150°C, insulated
The bypass is easily bendable.

M24x1,5 male thread to M30x1,5 female thread

Material: Metal
Temperature range: -100°C...350°C
Length: 100 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 150 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 200 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 300 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

M30x1,5 female thread to R1/2 male thread

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 100 cm
Connection: M24x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 150 cm
Connection: M24x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 200 cm
Connection: M24x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 300 cm
Connection: M24x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

External pressure sensor M30x1,5
for VPC bypass
(Connection on VPC)

External pressure sensor M38x1,5
for VPC bypass
(Connection on VPC)

External pressure sensor M24x1,5
for VPC bypass
(Connection on VPC)

Temperature range: -20°C ... 150°C, insulated
The bypass is easily bendable.

Temperature range: -20°C ... 150°C, insulated
The bypass is easily bendable.





Welding end adapter to M24x1,5 female

Temperature range: -20°C ... 150°C, insulated
The bypass is easily bendable.

Temperature range: -40°C...180°C
Nominal width: 6 mm
Material: Silicone
Silicone hoses are not suitable for heat transfer fluids which contain Silicone.
Please check the safety data sheet of the planned heat transfer fluid before using it.
Sold per meter





Upgrade package with the following additional features
(compared to E-grade "Basic"):
- Temperature control mode (Internal/Process)
- Process data logging direct to USB stick
- Display resolution 0,01°C
- Programmer with 3 programs (max. 15 steps)
- Ramp function (linear)
- TAC (True Adaptive Control)
- Saving/loading via USB
(package: 2)

Upgrade package with the following additional features
(compared to E-grade "Basic"):
- Temperature control mode (Internal/Process)
- Process data logging direct to USB stick
- Display resolution 0,01°C
- TAC (True Adaptive Control)
- Saving/loading via USB
- Programmer with 10 programs (max. 100 steps)
- Calendar start
- Ramp function (linear and non-Linear)
- User menus can be customised (Administrator Level)
- 2nd set point
(package: 3)


- for external open baths
- only suitable for units with pressure and suction pump
Download: Installation Guide




Material: Metal
Temperature range: -50...200°C
Length: 100 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -50°C...200°C
Length: 150 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -50°C...200°C
Length: 200 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -50°C...200°C
Length: 300 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 100 cm
Connection: M30x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 150 cm
Connection: M30x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 200 cm
Connection: M30x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 300 cm
Connection: M30x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 100 cm
Connection: M38x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 150 cm
Connection: M38x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 200 cm
Connection: M38x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Industrial plastic material hose with braiding
Temperature range: -60°C...260°C
Length: 300 cm
Connection: M38x1,5
Max. pressure at 20°C: 6 bar
Internal diameter: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Manually adjustable bypass G1 1/4 with connection for manometer, for Unichillers
Temperature range: -20°C ... 150°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

- Operating temperature range: -100...300 °C
- Temperature stability at -10°C: 0,002 K
- Pump connection: M30x1,5
- Dimension (W x D x H): 300 x 300 x 566 mm
- Width with overflow vessel: 440 mm
- Bath opening (Ø x H): 118 x 385 mm
- Bath volume: 7 liters
- Connections: M30x1,5
Following bath covers are optionally available:
- PTFE -100...200°C #6365
- Stainless steel -100...300°C #6367
- PE plastic #6366


Temperature range for:
- open/closed systems: -10°C...120°C
Material: synthetic oil
Colour: colourless, clear
Viscosity at 25°C: 8 mm²/s
Can: 5 liters
Not suitable for use with Unichillers

Temperature range for:
- open/closed systems: -10°C...120°C
Material: synthetic oil
Colour: colourless, clear
Viscosity at 25°C: 8 mm²/s
Can: 10 liters
Not suitable for use with Unichillers

- regulated, including T-piece
- for Unistats with M30x1,5 connection
- Protection class IP 20 (indoor installation only)
- Bypass loose (is not mounted on the unit)
- Mounted in the pipework (before application), can be mounted permanently or via hose
- max. differential pressure 6 bar
- Installation on the unit only possible in combination with Huber hose M30x1,5
- permissible temperature range: -90°C ... 200°C

- regulated, including T-piece
- for Unistats with G 1 1/4 connection
- Protection class IP 20 (indoor installation only)
- Bypass loose (is not mounted on the unit)
- Mounted in the pipework (before application), can be mounted permanently or via hose
- max. differential pressure 6 bar
- permissible temperature range: -90°C ... 200°C

- regulated, including T-piece
- for Unichillers with G 3/4 connection
- Protection class IP 20 (indoor installation only)
- Bypass loose (is not mounted on the unit)
- Mounted in the pipework (before application), can be mounted permanently or via hose
- max. differential pressure 6 bar
- permissible temperature range: -90°C ... 200°C

Bath cover isolated, for stainless steel bath 5,5 liters (#6052)

Bath cover isolated, for stainless steel bath 11 liters (#6053)

Bath cover isolated, for stainless steel bath 22 liters (#6054)

M16x1 female thread to M16x1 male thread


Sensor open in protective pipe Ø 8 mm
(Pt100) with 1,5 m cable
Sensor length: 170 mm, Ø 8 mm

Insulated stainless steel bath with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume: according to customer specifications, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)





Material: Metal
Temperature range: -100°C...350°C
Length: 300 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Temperature range for:
- open/closed systems: -90°C...55°C
- Unistats (only closed): -90°C...170°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 2 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: -90°C...55°C
- Unistats (only closed): -90°C...170°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 2 mm²/s
Can: 10 liters


Temperature range for:
- open/closed systems: -80°C...100°C
- Unistats (only closed): -80°C...250°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 7 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: -80°C...100°C
- Unistats (only closed): -80°C...250°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 7 mm²/s
Can: 10 liters



with coupling and plug (Lemosa)
Cable length: 3 m






Control cable Compatible Control CC
complete / open (3m)

Insulated stainless steel bath with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume: according to customer specifications, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel bath with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume: according to customer specifications, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel bath with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume: according to customer specifications, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)



Temperature range: -60°C...180°C
Nominal width: 8 mm
Material: PTFE
Sold per meter

Temperature range: -60°C...180°C
Nominal width: 12 mm
Material: PTFE
Sold per meter








The cover is drilled at the factory according to your specifications. Please calculate 20,00 EUR per hole (Ø4 - Ø10 mm).
Please let us know the desired number of holes and their diameter.

The cover is drilled at the factory according to your specifications. Please calculate 20,00 EUR per hole (Ø4 - Ø10 mm).
Please let us know the desired number of holes and their diameter.

Thickness: 20,5 mm
Internal diameter: 43,5 - 47,5 mm
Sold per meter

Thickness: 21 mm
Internal diameter: 49,5 - 51,5 mm
Sold per meter

Thickness: 21,5 mm
Internal diameter: 58 - 60 mm
Sold per meter

Material: Metal
Temperature range: -100°C...350°C
Length: 150 cm
Nominal width: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps.








Thickness: 13 mm
Internal diameter: 16 mm
Sold per meter




suitable for use with adjustable base #40763

suitable for use with adjustable base #40681



Cable connection 6 mm
Ext. level and release




Width bath opening W x D: 290 x 320 mm
Bath depth: 200 mm
Bath volume: 15 liters
Dimensions W x D x H: 350 x 375 x 256 mm
All stainless steel baths are designed to operate up to a maximum temperature of +200°C.

Width bath opening W x D: 290 x 500 mm
Bath depth: 200 mm
Bath volume: 25 liters
Overall dimensions W x D x H: 350 x 555 x 256 mm
All stainless steel baths are designed to operate up to a maximum temperature of +200°C.


for polycarbonate baths 112A, 118A, 130A
connection screw M12x1,5

for polycarbonate baths 106A to 110A
Immersion depth 50 mm
Bore holes 12 x Ø22

for polycarbonate baths 106A to 110A
Immersion depth 55 mm
Bore holes 20 x Ø17

for polycarbonate baths 106A to 110A
Immersion depth 95 mm
Bore holes 20 x Ø17

for polycarbonate baths 106A to 110A
Immersion depth 45 mm (Hemolyses)
Bore holes 30 x Ø13

for polycarbonate baths 106A to 110A
Immersion depth 50 mm
Bore holes 6 x Ø30

for polycarbonate baths 106A to 110A
Immersion depth 25 mm (Eppendorf)
Bore holes 36 x Ø11


A breather controller is available as an accessory for our Unistats. This allows to realise an inert gas overlay of the thermal fluid in the expansion vessel. Advantages of the breather controller are a longer life-time of the heat transfer fluid as a result of the reduced oxidation as well as an extended temperature range. The breather control limits the pressure and consists of the atmospheric sealing kit comprising of the following parts on a mounting plate:
- Atmosperic sealing kit
- Pressure regulator 20-200 mbar
- Safety valve 200 mbar opening
- Bubble counter
- Connection hose
- Max. pressure 1 bar
- Connection G1/2
Unit not suitable for outdoor installation - can not be installed in a closed room (room must be adequately ventilated).


Calibration bend M30x1,5 with sensor pocket for sensor Ø 6 mm / length 165 mm
Female thread on short side

External pressure sensor M16x1
for VPC variable speed pump
(Com.G@te required)

External pressure sensor M24x1,5
for VPC variable speed pump
(Com.G@te required)

External pressure sensor M30x1,5
for VPC variable speed pump
(Com.G@te required)

- regulated, including T-piece
- for Unistats with M24x1,5 connection
- Protection class IP 20 (indoor installation only)
- Bypass loose (is not mounted on the unit)
- Mounted in the pipework (before application), can be mounted permanently or via hose
- max. differential pressure 6 bar
- Installation on the unit only possible in combination with Huber hose M24x1,5
- permissible temperature range: -90°C ... 200°C

- regulated, including T-piece
- for Unistats with M38x1,5 connection
- Protection class IP 20 (indoor installation only)
- Bypass loose (is not mounted on the unit)
- Mounted in the pipework (before application), can be mounted permanently or via hose
- max. differential pressure 6 bar
- Installation on the unit only possible in combination with Huber hose M38x1,5
- permissible temperature range: -90°C ... 200°C

for baths 112A, 118A, 212B to 225B and K12 to K25
Immersion depth 100 mm
Bore holes 36 x Ø18

for baths 112A, 118A, 212B to 225B and K12 to K25
Immersion depth 70 mm
Bore holes 45 x Ø13

for baths 112A, 118A, 212B to 225B and K12 to K25
Immersion depth 100 mm
Bore holes 46 x Ø18

for baths 112A, 118A, 212B to 225B and K12 to K25
Immersoin depth 70 mm
Bore holes 58 x Ø13



Dimensions (L x W x H): 265 x 145 x 185 mm

Dimensions (L x W x H): 245 x 240 x 189 mm

Dimensions (L x W x H): 210 x 282 x 205 mm
with drain on short side

Dimensions (L x W x H): 250 x 420 x 205 mm
with drain on short side

Dimensions (L x W x H): 370 x 520 x 205 mm
with drain on short side

Insulated stainless steel baths with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume according to customer specification, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel baths with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume according to customer specification, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel baths with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume according to customer specification, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel baths with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume according to customer specification, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel baths with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume according to customer specification, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

Insulated stainless steel baths with customised dimensions and bath volume. The drain is on the short side as standard but can be also fitted on the long side on request (please add the suffix "-L" to the order number).
Dimensions/bath volume according to customer specification, please specify when ordering.
Available options (at additional cost):
- inlet and outlet connections into the bath (direct temperature control)
- inlet and outlet connections into the double-wall (indirect temperature control)

with 1,5 m cable
Sensor length: 400 mm, Ø 8 mm

Temperature range: -20°C...60°C
Length: variable
Internal diameter: 12 mm
Material: PVC
Sold per meter

Temperature range: -20°C...60°C
Length: variable
Internal diameter: 8 mm
Material: PVC
Sold per meter

Temperature range: -20°C...60°C
Length: variable
Max. pressure at 20°C: low pressure
Internal diameter: 3,2 mm
Thickness: 1,0 mm
Material: PVC
Sold per meter

Temperature range: -25°C...110°C
Length: variable
Max. pressure at 20°C: low pressure
Internal diameter: 12 mm
Material: NBR
Sold per meter

Temperature range: -25°C...110°C
Length: variable
Max. pressure at 20°C: low pressure
Internal diameter: 8 mm
Material: NBR
Sold per meter

Temperature range.: -40°C...180°C
Nominal width: 12 mm
Material: Silicone
Silicone hoses are not suitable for heat transfer fluids which contain Silicone.
Please check the safety data sheet of the planned heat transfer fluid before using it.
Sold per meter

Temperature range: -40°C...180°C
Nominal width: 8 mm
Material: Silicone
Silicone hoses are not suitable for heat transfer fluids which contain Silicone.
Please check the safety data sheet of the planned heat transfer fluid before using it.
Sold per meter

Temperature range: -20°C...180°C
Length: variable
Max. pressure at 20°C: low pressure
Internal diameter: 8 mm
Material: FKM
Sold per meter

Thickness: 6 mm
Internal diameter: 16 mm
Sold per meter

Thickness: 6 mm
Internal diameter: 13 mm
Sold per meter

Material: Metal
Temperature range: -100°C...350°C
Length: 100 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 150 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps







with 1,5 m cable
Sensor length: 200 mm, Ø 6 mm

Calibration insert CC-315B
Also required: Hose #9608

Material: Metal
Temperature range: -100°C...350°C
Length: 200 cm
Connection: M16x1
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

with 1,5 m cable
Sensor length: 180 mm, Ø 6 mm

RS232 control cable
from: Huber unit / Com.G@te, 9 pin Sub-D plug (male)
to: PC / Notebook, 9 pin Sub-D socket (female)
Length 3 m

Also required: Hose #9609

Temperature range for:
- open/closed systems: 20°C...190°C
Material: mineral oil
Colour: light yellow
Viscosity at 25°C: 40 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: 20°C...190°C
Material: mineral oil
Colour: light yellow
Viscosity at 25°C: 40 mm²/s
Can: 20 liters

Temperature range for:
- open/closed systems: 20°C...225°C
- Unistats (only closed): 20°C...275°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 50 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: 20°C...225°C
- Unistats (only closed): 20°C...275°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 50 mm²/s
Can: 10 liters

Temperature range for:
- open/closed systems: -20°C...195°C
- Unistats (only closed): -20°C...235°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 20 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: -20°C...195°C
- Unistats (only closed): -20°C...235°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 20 mm²/s
Can: 10 liters

Temperature range for:
- open/closed systems: -40°C...165°C
- Unistats (only closed): -40°C...220°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 10 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: -40°C...165°C
- Unistats (only closed): -40°C...220°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 10 mm²/s
Can: 10 liters

Temperature range for:
- open/closed systems: -60°C...115°C
- Unistats (only closed): -60°C...200°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 5 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: -60°C...115°C
- Unistats (only closed): -60°C...200°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 5 mm²/s
Can: 10 liters

Temperature range for:
- open/closed systems: -80°C...55°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 3 mm²/s
Can: 5 liters

Temperature range for:
- open/closed systems: -80°C...55°C
Material: silicone oil
Colour: colourless, clear
Viscosity at 25°C: 3 mm²/s
Can: 10 liters

Temperature range depends on mixing ratio
Material: Monoethylenglycol, concentrate
Mixing ratio: 50% MEG / 50% water
Colour: light yellow, clear
Viscosity at 25°C: approx. 2 mm²/s
Can: 10 liters

Temperature range depends on mixing ratio
Material: Monoethylenglycol, concentrate
Mixing ratio: 50% MEG / 50% water
Colour: light yellow, clear
Viscosity at 25°C: approx. 2 mm²/s
Can: 50 liters



Temperature range: -20°C ... 150°C, insulated
The bypass is easily bendable.

Material: Metal
Temperature range: -100°C...350°C
Length: 100 cm
Connection: M30x1,5
Nominal width: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 200 cm
Connection: M30x1,5
Nominal width: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 300 cm
Connection: M30x1,5
Nominal width: 20 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps








Temperature range: -10 ... +180°C (max. 6 bar at + 180°C)






M30x1,5 female thread to M30x1,5 male thread


Valid only for Unistats
Temperature range for:
- closed systems: -90°C...170°C
- closed systems (with Inertgas): -90°C...200°C
Colour: yellowish, clear
Viscosity at 25°C: 2 mm²/s
Can: 10 liters

Material: Metal
Temperature range: -100°C...350°C
Length: 50 cm
Connection: M30x1,5
Nominal width: 20 mm

Also required: Hose #9609


M38x1,5 female thread to M30x1,5 male thread

Material: Metal
Temperature range: -100°C...350°C
Length: 100 cm
Connection: M38x1,5
Nominal width: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 150 cm
Connection: M38x1,5
Nominal width: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 200 cm
Connection: M38x1,5
Nominal width: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -100°C...350°C
Length: 300 cm
Connection: M38x1,5
Nominal width: 25 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps


Valid only for Unistats
Temperature range for:
- closed systems: 20°C...170°C
- closed systems (with Inertgas): 20°C...340°C
Colour: orange, clear
Viscosity at 25°C: 32 mm²/s
Can: 5 liters

Valid only for Unistats
Temperature range for:
- closed systems: 20°C...170°C
- closed systems (with Inertgas): 20°C...340°C
Colour: orange, clear
Viscosity at 25°C: 32 mm²/s
Can: 10 liters

Width bath opening (W x D): 235 x 290 mm
Bath depth: 150 mm
Bath volume: 8,5 liters
Overall dimensions (W x D x H): 290 x 350 x 206 mm
All stainless steel baths are designed to operate up to a maximum temperature of +200°C.

Width bath opening (W x D): 290 x 320 mm
Bath depth: 150 mm
Bath volume: 12 liters
Overall dimensions (W x D x H): 350 x 375 x 206 mm
All stainless steel baths are designed to operate up to a maximum temperature of +200°C.

Width bath opening (W x D): 290 x 500 mm
Bath depth: 150 mm
Bath volume: 20 liters
Overall dimensions (W x D x H): 350 x 555 x 206 mm
All stainless steel baths are designed to operate up to a maximum temperature of +200°C.

M38x1,5 female thread to M38x1,5 male thread

Temperature range: -10 ... +180°C (max. 10 bar at +180°C)


M24x1,5 female thread to M30x1,5 male thread


Welding end adapter to M38x1,5 female

Material: Metal
Temperature range: -120°C...400°C
Length: 100 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps.

Material: Metal
Temperature range: -120°C...400°C
Length: 150 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps.

Material: Metal
Temperature range: -120°C...400°C
Length: 200 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps

Material: Metal
Temperature range: -120°C...400°C
Length: 300 cm
Connection: M24x1,5
Nominal width: 12 mm
Insulation: Special insulation with additional smooth silicone hose, ends covered with silicone caps




Dimensions (L x W x H): 172 x 78 x 110 mm

Dimensions (L x W x H): 162 x 80 x 124 mm

Dimensions (L x W x H): 194 x 80 x 147 mm

for all baths/thermostats
connection screw G3/8"
with sealing cap
(not suitable for polycarbonate baths 112A, 118A, 130A)

M24x1,5 female thread to 3/4NPT female thread


Temperature range: -20°C ... 150°C, insulated
The bypass is easily bendable.


Manually adjustable bypass M24x1,5 with connection for manometer for Unistats
Extended temperature range: -60°C ... 200°C, non-insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64191
Manometer 0-2,5 bar #64192
Manometer 0-4 bar #63933
Manometer 0-10 bar #64193
The bypass is easily bendable.

Cooling water control valve for use on circulators with Pilot ONE controller. The control valve is connected to a cooliing coil, this can be controlled by the Pilot ONE.
Permissible temperature range: -20°C...+80°C
Max. pressure: 6 bar
Permitted medium: water/ water-MEG mixture
Protection class: IP20
Connection cooling circuit: hose connection 6mm / 8mm
Connection length: 1.8 m
Connection electrical: 15 pin Sub-D port (Pilot ONE)
1.) Heating bath circulators CC-202C, CC-205B, CC-304B, CC-308B and CC315B (cooling coil fitted as standard)
2.) Heating bath circulators CC-104A to CC-118A in combination with optional cooling coil #30554
3.) Wärme-Badthermostate CC-208B to CC-225B in combination with optional cooling coil #30564
4.) Huber devices with cooling coils NW6 or NW8
Please note that this is not suitable for use with KISS circulators!

Remote control EEX Panel 15.0"
with stainless steel housing for wall mounting for Huber temperature control units with Pilot ONE
Explosion protection zones 1 and 21:
ATEX marking
- Gases/vapours: II 2G Ex db eb q [ib] IIC T4 Gb
- Dust: II 2D Ex tb IIIC T120 °C Db
IECEx marking
- Gases/vapours: Ex db eb q [ib] IIC T4 Gb
- Dust: Ex tb IIIC T120 °C Db
- Power Supply: AC 100-230V
- Protection class: IP54
- Weight: 55 kg
- Storage: 128 GB SSD hard disk space, 8 GB RAM memory
- Operating system: Windows 10 IoT LTSB 64-bit
- Software package: Remote software incl. licence key, SpyControl #66108 (optional)
- Ambient temperature range: 0 °C to 50 °C
- Ethernet cable, shielded, 25 m, CAT6
- Stainless steel housing with built-in POLARIS Panel PC 15" for wall mounting
- Housing material: stainless steel 1.4404
- Protection class: IP54
- Dimensions (W x D x H): 650 x 150 x 550 mm

Location: hose side
Temperature range: -90°C...230°C
Disconnect temperature: 20°C
Connection: M30x1,5
Material: 1.4404; HTF contact, 1.4571
Max. pressure at 20°C: 25 bar
Internal diameter: 20 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive appliances are to be used for temperature control, we strongly recommend using the optionally available adapter #10417 to connect an operator-side pressure relief device in the application-side return line. This protects your glass apparatus from the risk of damage due to bursting.
Download: Installation Guide
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Location: temperature control unit, application
Temperature range: -90°C...230°C
Disconnect temperature: 20°C
Connection: M30x1,5
Material: 1.4404; HTF contact 1.4571
Max. pressure at 20°C: 25 bar
Internal diameter: 20 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive appliances are to be used for temperature control, we strongly recommend using the optionally available adapter #10417 to connect an operator-side pressure relief device in the application-side return line. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

M30x1,5 female to M30x1,5 male adapter for connection of a pressure relief device with a Rp 1/4 connection, thermally decoupled (as optional accessory for quick disconnect adapters #10406, #10407)
This adapter enables the connection of a pressure relief device in the return line of the application. Its use is strongly recommended for the temperature control of pressure-sensitive apparatus (e.g. glass reactor) in conjunction with our quick-release fittings (#10406, #10407). By connecting a pressure relief device on the operator side using the adapter, you protect your glass apparatus from the risk of damage due to bursting.
The adapter is equipped with M30x1.5 connection threads on both sides. The connection for an operator-side safety device is thermally decoupled and designed with an Rp thread.

Flow rate measuring device to build into the temperature control fluid circuit for measurement and control of Heat Transfer Fluids flow rate. The flow rate can be displayed directly on the Pilot ONE and also be transmitted via the digital interfaces (USB, RS232, LAN and optional RS485, Profibus). It is also possible to control the flow, therefore a temperature control unit with an integrated VPC-Bypass or an external VPC-Bypass as an accessory is required.
The flow rate measurement allows essential functions such as finding the Kinetics/Dynamics of reaction synthesis and crystallisation, heat flow investigation and scale-up in process technology. Further information available on request.
Flow rate measuring device MID, only suitable for conductive heat transfer fluids:
- Temperature range: -40...130°C
- Flow rate: 1...300 l/min
- Measurement accuracy: 3,7...0,7 %

Flow rate measuring device to build into the temperature control fluid circuit for measurement and control of Heat Transfer Fluids flow rate. The flow rate can be displayed directly on the Pilot ONE and also be transmitted via the digital interfaces (USB, RS232, LAN and optional RS485, Profibus). It is also possible to control the flow rate, therefore a temperature control unit with an integrated VPC-Bypass or an external VPC-Bypass as an accessory is required.
The flow rate measurement allows essential functions such as finding the Kinetics/Dynamics of reaction synthesis and crystallisation, heat flow investigation and scale-up in process technology. Further information available on request.
Flow rate measuring device MID, only suitable for conductive heat transfer fluids:
- Temperature range: -40...130°C
- Flow rate: 0,2...100 l/min
- Measurement accuracy: 8...0,6 %

The international guarantee from Huber offers worldwide guarantee coverage for distributors, OEM partners etc.
Your advantages:
- Comprehensive care free package
- Professional repair work
- Fast execution of guarantee repairs
- Predictable guarantee costs
- Minimising downtime
- Simple handling of guarantee cases
- No further costs for repairs during guarantee

The E-grade Explore for Unistats is a development tool for chemical processes which gives access to the following values:
- Performance: Heating or cooling capacity of the system
- Temperature values: Setpoint, internal, process, return
- Temperature differences: ?T internal-return, ?T process-return, ?T process-internal
- Circulation pump: Pressure / speed (depending on model)

The Profibus Gateway DP-V1 enables the connection of Huber temperature control machines to Profibus systems, offering comprehensive facilities for data communication within SPS and process control systems.
The Profibus Gateway DP-V1 has a configurable range of functions, the PLC must therefore support acyclic configuration.
For units with Pilot ONE controller
Power Supply: 100-240V 1~/2~ 50/60Hz
Accessories (included): Mounting Bracket, Connection cable, Power cable
Requirement: Controller (SPS) must be capable for DPV1
Download: Device configuration file

Connection socket (Lemosa) for connecting a Pt100 measuring sensor, suitable for Huber units with OLÉ controller (only for measuring, no external temperature control).
Only available factory-fitted (or retrofitting by a Huber service partner).

Location: temperature control unit, application
Temperature range: -75°C...230°C
Disconnect temperature: 20°C
Connection: M24x1,5
Material: 1.4307 or better
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C.

Location: hose side
Temperature range: -75°C...230°C
Disconnect temperature: 20°C
Connection: M24x1,5
Material: 1.4307 or better
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, our quick-release couplings are recommended. The quick-release couplings fulfil the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick-release couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

The OPC UA (OPC Unified Architecture) communication protocol semantically describes data and thus allows a data exchange between automation systems without the need to program a driver. Huber temperature control units with Pilot ONE can already communicate via the modern OPC UA protocol by using the E-grade OPC UA.

Flow rate measuring device to build into the temperature control fluid circuit for measurement and control of Heat Transfer Fluids flow rate. The flow rate can be displayed directly on the Pilot ONE and also be transmitted via the digital interfaces (USB, RS232, LAN and optional RS485, Profibus). It is also possible to control the flow rate, therefore a temperature control unit with an integrated VPC-Bypass or an external VPC-Bypass as an accessory is required.
The flow rate measurement allows essential functions such as finding the Kinetics/Dynamics of reaction synthesis and crystallisation, heat flow investigation and scale-up in process technology. Further information available on request.
Flow rate measuring device Turbine, suitable for all Huber heat transfer fluids:
- Temperature range: -100...350°C
- Flow rate: 6...60 l/min
- Measurement accuracy: 2 %

Flow rate measuring device to build into the temperature control fluid circuit for measurement and control of Heat Transfer Fluids flow rate. The flow rate can be displayed directly on the Pilot ONE and also be transmitted via the digital interfaces (USB, RS232, LAN and optional RS485, Profibus). It is also possible to control the flow rate, therefore a temperature control unit with an integrated VPC-Bypass or an external VPC-Bypass as an accessory is required.
The flow rate measurement allows essential functions such as finding the Kinetics/Dynamics of reaction synthesis and crystallisation, heat flow investigation and scale-up in process technology. Further information available on request.
Flow rate measuring device Turbine, suitable for all Huber heat transfer fluids:
- Temperature range: -100...350°C
- Flow rate: 15...150 l/min
- Measurement accuracy: 2 %

Temperature range depends on mixing ratio
Material: Monoethylenglycol, concentrate
Mixing ratio: 50% MEG / 50% water
Colour: light yellow, clear
Viscosity at 25°C: approx. 2 mm²/s
Can: 5 liters

Connection socket (Lemosa) for connecting a Pt100 measuring sensor, suitable for Huber units with KISS controller (only for measuring, no external temperature control).
Only available factory-fitted (or retrofitting by a Huber service partner).

Only available factory-fitted (or retrofitting by a Huber Service partner)


Plastic hose with insert
Temperature range: -30°C...100°C
Length: variable
Material: NBR
Connection 1: Cable end open
Connection 2: Cable end open
Max. pressure at 20°C: 30 bar
Nominal diameter: 8 mm
Outer diameter: 16,3 mm
Colour: black
Insert: textile
Sold per meter

Plastic hose with insert
Temperature range: -30°C...100°C
Length: variable
Material: NBR
Connection 1: Cable end open
Connection 2: Cable end open
Max. pressure at 20°C: 30 bar
Nominal diameter: 10 mm
Outer diameter: 17,6 mm
Colour: black
Insert: textile
Sold per meter

Temperature range: -45°C...220°C
Connection: M16x1 male
location: hose side
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Temperature range: -45°C...220°C
Connection: M16x1 male
Location: Temperature control unit, application
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Location: hose side
Temperature range: -45°C...220°C
Disconnect temperature: 20°C
Connection: M24x1,5
Material: 1.4307 or better
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Location: temperature control unit, application
Temperature range: -45°C...220°C
Disconnect temperature: 20°C
Connection: M24x1,5
Material: 1.4307 or better
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Temperature range: -75°C...230°C
Connection: M16x1 male
Location: hose side
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Temperature range: -75°C...230°C
Connection: M16x1 male
Location: Temperature control unit, application
Max. pressure at 20°C: 25 bar
Internal diameter: 12 mm
Temperature control units are usually connected to the application (e.g. reactor) using insulated temperature control hoses. If the applications on the temperature control unit need to be changed frequently, we recommend our quick-release couplings. The quick couplings meet the special requirements of temperature control technology and reliably prevent temperature control fluid from escaping. The quick couplings cause only low pressure losses and thus ensure good performance of the overall system.
If pressure-sensitive equipment is to be used for temperature control, we recommend the use of a pressure relief device on the operator side in the return line on the application side. This protects your glass apparatus from the risk of damage due to bursting.
Note: When using ethanol as heat transfer fluid: min. working temperature limit -60°C

Manually adjustable bypass M16x1 with connection for manometer, for Unistats
Temperature range: -60°C ... 200°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

Material: Metal
Temperature range: -40°C...140°C
Length: 100 cm
Connection: G3/4
Nominal width: 19 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 150 cm
Connection: G3/4
Nominal width: 19 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 200 cm
Connection: G3/4
Nominal width: 19 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 300 cm
Connection: G3/4
Nominal width: 19 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 100 cm
Connection: G1
Nominal width: 25 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 150 cm
Connection: G1
Nominal width: 25 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 200 cm
Connection: G1
Nominal width: 25 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 300 cm
Connection: G1
Nominal width: 25 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 100 cm
Connection: G1 1/4
Nominal width: 32 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 150 cm
Connection: G1 1/4
Nominal width: 32 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 200 cm
Connection: G1 1/4
Nominal width: 32 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Material: Metal
Temperature range: -40°C...140°C
Length: 300 cm
Connection: G1 1/4
Nominal width: 32 mm
Insulation: Special insulation with silicone cover, ends secured and covered with silicone caps

Designed to compensate for pressure loss in external systems the Unipump is made of stainless steel. The Unipump is connected in series with the pump of the Unistat, Unichiller or Compatible Control circulator and can be controlled via the voltfree contact of the Com.G@te (Option).
Temperature range: -120 ... 300 °C
Pressure pump max.: 55 l/min / 1,0 bar
Pump connection: M24x1,5
Power supply: 208-240V 1~ 50/60Hz

Closed magnetic-coupled circulation pump made of stainless steel. Designed to compensate for pressure loss in external systems the Unipump is made of stainless steel. The Unipump is connected in series with the pump of the Unistat, Unichiller or Compatible Control circulator and can be controlled via the voltfree contact of the Com.G@te (Option).
Temperature range: -120 ... 350 °C
Pressure pump max. 110 l/min / 2 bar
Pump connection: M38x1,5 male
Power supply: 380V- 480V 3~ 50/60Hz
Dimensions (W x D x H): 275 x 420 x 295 mm

Material: Metal
Temperature range: -90°C...200°C
Length: 100 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 40 mm
Insulation: Foam insulation, shrinked tubing as end caps

Material: Metal
Temperature range: -90°C...200°C
Length: 150 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 40 mm
Insulation: Foam insulation, shrinked tubing as end caps

Material: Metal
Temperature range: -90°C...200°C
Length: 200 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 40 mm
Insulation: Foam insulation, shrinked tubing as end caps

Closed magnetic-coupled circulation pump made of stainless steel. Designed to compensate for pressure loss in external systems the Unipump is made of stainless steel. The Unipump is connected in series with the pump of the Unistat, Unichiller or Compatible Control circulator and can be controlled via the voltfree contact of the Com.G@te (Option).
Temperature range: -120 ... 350 °C
Pressure pump max. 120 l/min / 4 bar
Pump connection: M38x1,5 male
Power supply: 380V-480V 3~ 50/60Hz
Dimensions: 275x420x295 mm

Material: Metal
Temperature range: -90°C...200°C
Length: 300 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 40 mm
Insulation: Foam insulation, shrinked tubing as end caps

Material: Metal
Temperature range: -90°C...200°C
Length: 100 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 50 mm
Insulation: Foam insulation, shrinked tubing as end caps

Material: Metal
Temperature range: -90°C...200°C
Length: 150 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 50 mm
Insulation: Foam insulation, shrinked tubing as end caps

Material: Metal
Temperature range: -90°C...200°C
Length: 200 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 50 mm
Insulation: Foam insulation, shrinked tubing as end caps

Calibration bend M24x1,5 with sensor pocket for sensor Ø 6 mm / length 160 mm

Also required: Hose #9609

Thickness: 19 mm
Internal diameter: 19 mm
Sold per meter

Thickness: 19 mm
Internal diameter: 28 mm
Sold per meter

Thickness: 19 mm
Internal diameter: 35 mm
Sold per meter

Thickness: 19 mm
Internal diameter: 42 mm
Sold per meter

Mounting bracket for mounting the Pilot ONE wall bracket at the side of the device


Temperature sensor Pt100, G3/4", for fluid outlet or return

Manually adjustable bypass M30x1,5 for Unistats
Extended temperature range: -60°C ... 200°C, non-insulated
The bypass is easily bendable.

Manually adjustable bypass M16x1 for Unistats, benchtop models
Extended temperature range: -60°C ... 200°C, non-insulated
The bypass is easily bendable.

Manually adjustable bypass M24x1,5 for Unistats
Extended temperature range: -60°C ... 200°C, non-insulated
The bypass is easily bendable.

Manually adjustable bypass M38x1,5 for Unistats
Extended Temperature range: -60°C ... 200°C, non-insulated
The bypass is easily bendable.

Manually adjustable bypass G3/4 for Unichiller
Extended temperature range: -60°C ... 200°C, non-insulated
The bypass is easily bendable.

Manually adjustable bypass G1 1/4 for Unichiller
Extended temperature range: -60°C ... 200°C, non-insulated
The bypass is easily bendable.

CAN Switch for remote operation or external installation:
- distribution switch to connect multiple accessories simultaneously such as the ComG@te, External VPC-Bypass, etc.
- for the remote operation of Huber units

Material: Metal
Temperature range: -90°C...200°C
Length: 300 cm
Connection: Flange EN1092-1 Typ 11
Nominal width: 50 mm
Insulation: Foam insulation, shrinked tubing as end caps

Manually adjustable bypass G3/4 with connection for manometer, for Unichiller
Temperature range: -20°C ... 150°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

Manually adjustable bypass M16x1 with connection for manometer, for Unistats
Temperature range: -20°C ... 140°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

Manually adjustable bypass M30x1,5 with connection for manometer, for Unistats
Temperature range: -20°C ... 150°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

Calibration bend M16x1 with sensor pocket for sensor Ø 4 mm / length 75 mm

For calibration of an internal sensor M38x1,5 for sensor Ø 6 mm / length 160 mm

Manually adjustable bypass M24x1,5 with connection for manometer, for Unistats
Temperature range: -20°C ... 150°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

Manually adjustable bypass M38x1,5 with connection for manometer, for Unistats
Temperature range: -20°C ... 150°C, insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64190
Manometer 0-2,5 bar #64189
Manometer 0-4 bar #54398
Manometer 0-10 bar #54399
The bypass is easily bendable.

Cover set for interfaces (USB, RS232, Pt100) in the colour RED for KISS heating and cooling circulators.
To replace the grey standard covers. Available free of charge with new orders of any KISS models. Please specify article number when ordering.

Cover set for interfaces (USB, RS232, Pt100) in the colour BLUE for KISS heating and cooling circulators.
To replace the grey standard covers. Available free of charge with new orders of any KISS models. Please specify article number when ordering.

Software solution for controlling Huber units as well as for visualisation and documentation of process relevant data. The installation package contains a free version, a 30 days trial version and paid full version with license key entry.
The software SpyControl is available in the download section.
Suitable for PC and notebook with Microsoft Windows operating system.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10450 is included.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10703 is included.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.

Temperature range: -20 ... +140°C (max. 6 bar at +140°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10159 is included.

Temperature range: -20 ... +140°C (max. 6 bar at +140°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -20 ... +140°C (max. 6 bar at +140°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -20 ... +140°C (max. 6 bar at +140°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 60 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 20 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Octagon 8 port - manifold
with CPC Quickconnects, valved coupling
high grade synthetic material -40 ... +80 °C
chemically resistant and thermally robust
Max. pressure: 1,5 bar
Tube connection:
Inlet: 3/8" (approx. 10 mm)
Outlet: 1/4" (approx. 8 mm)


Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.


Electronic module with insertion slot for Pilot ONE controller for Unistats
Pilot ONE is not included in delivery.

Controller Pilot ONE for CC circulators, Unichillers, Unistats


Glass accessory set for cold trap CT50 Single OLÉ
Consisting of:
#503344 - glass trap body
#503345 - 3 way vacuum stopcock adapter
#503346 - 1-liter receiver flask
#503347 - quick release clamp 100 mm
#504544 - O-Ring DN100

USB control cable
from: controller Pilot ONE, Mini-USB
to: PC / Notebook, USB Type A
Length 3 m
for data recording, data communication and firmware updates

RS232 control cable
from: Huber unit, 15 pin Sub-D plug (male)
to: PC / Notebook, 9 pin Sub-D socket (female)
Length 3 m
This cable is required to use the 15 pins RS232 interface on Unistat models.

Touch pen set for Pilot ONE controller for convenient pen operation even when wearing protective gloves. The set includes the touch pen and a holding device (self-adhesive) with a flexible spiral cord. This ensures that the pen is always ready to hand directly on the device and cannot get lost.

Manually adjustable bypass M30x1,5 with connection for manometer, for Unistats
Extended temperature range: -60°C ... 200°C, non-insulated
For this bypass one of the following pressure gauges must be ordered separately:
Manometer 0-1 bar #64191
Manometer 0-2,5 bar #64192
Manometer 0-4 bar #63933
Manometer 0-10 bar #64193
The bypass is easily bendable.

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 220-240V 1~/2~ 50/60Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 110-120V 1~ 50/60Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 220-240V 1~/2~ 50/60Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 110-120V 1~ 50/60 Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 110-120V 1~ 50/60 Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 230V 1~ 50/60 Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 220-240V 1~/2~ 50/60Hz

The refrigerated baths K6 to K25 use natural refrigerants.In combination with an immersion circulator these refrigerated bath systems offers active cooling, in continuous operation over the complete working range.
Power Supply: 110-120V 1~ 50/60 Hz

Temperature range: -60°C ... +200°C (max. 10 bar at +175°C)

Temperature range: -60 ... +200°C (max. 10 bar at +175°C)

Temperature range: -60°C ... +200°C (max. 10 bar at +175°C)

Temperature range: -60°C ... +200°C (max. 10 bar at +175°C)

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10159 is included.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10159 is included.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.

Temperature range: -80 to 300°C (max 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10703 is included.

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10450 is included.

Temperature range: -80 to 300°C (max 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.

with CPC Quickconnects, valved coupling
high grade synthetic material -40 ... +80 °C
chemically resistant and thermally robust
Pressure max.: 1,5 bar
Tube connection:
Inlet: 3/8" (approx. 10 mm)
Outlet: 1/4" (approx. 8 mm)

Temperature range: -80 to 300°C (max. 6 bar at 300°C)
Including universal mounting device for fixation at site.
To connect the multiway header to the temperature control unit, a hose in corresponding length is required.
For direct mounting on the temperature control unit, the 90° ellbow adapter #10538 is included.

The Profinet Gateway enables the connection of Huber temperature control machines to Profinet systems, offering comprehensive facilities for data communication within SPS and process control systems.
For units with Pilot ONE controller
Power Supply: 100-240V
Accessories (included): Power cable
Download: Device configuration file

The EtherCAT Gateway enables the connection of Huber temperature control machines to EtherCAT systems, offering comprehensive facilities for data communication within SPS and process control systems.
For units with Pilot ONE controller
Power Supply: 100-240V
Accessories (included): Power cable
Download: Device configuration file

The optional E-grade Remote GUI allows remote control of the Huber temperature control units with Pilot ONE. All functions that are available locally on the Pilot ONE can be displayed and operated identically via the Pilot Remote software on any PC / laptop operating with Microsoft Windows. It is ideal for remote monitoring or remote control within a network (LAN). For example, several Huber units in different rooms can be displayed centrally on one PC. The E-grade Remote GUI can be used to control the temperature control system either locally or from a PC. This allows centralised visualisation and operation.
The Pilot Remote software can be downloaded free of charge from our website.

The Profibus Gateway DP-V0 enables the connection of Huber temperature control machines to Profibus systems, offering comprehensive facilities for data communication within SPS and process control systems.
The Profibus Gateway DP-V0 has a defined range of functions, the available parameters are listed in the manual.
For units with Pilot ONE controller.
Power Supply: 100-240V
Accessories (included): Mounting Bracket, Connection cable, Power cable
Requirement: Controller (SPS) must be capable for DPV0
Download: Device configuration file

Float switch in sight glass Unistat
for extended safety of leakage monitoring, with cable and connector plug
for ECS socket on Unistat (Pilot ONE generation),
Com.G@te or Poko/ECS interface

Temperature range: -45 °C....150 °C
Fluid connection: M38x1,5 male
Dimensions (W x D x H): 397 x 545 x 586 mm
Compressed air max.: 4 bar
Power supply: 90-240V 1~/2~ 50/60Hz
Protection class: IP20
Useable: Free-Standing Unistats, Unimotive and Unichillers Tower
Heat transfer fluids: water-ethylene glycol mixtures
Solenoid valves: electrically controlled
Notes:
- Please specify the used device with serial number when ordering.
- Safety device against overpressure not included in the scope of delivery.
- The connection of the fluid return line to the temperature control system must be carried out by others.
- No excess pressure is permitted in the TCU during the active return of the liquid, i.e. a pressure equalisation must have been completed prior to the return of the fluid to the expansion vessel.

Piping kit for FCC Flow Control Cube MID/TURB/CORE I
for mounting the Flow Control Cube on top
Note:
The height of the temperature control unit increases by approx. 620 mm

Mounting kit for FCC Flow Control Cube MID/TURB/CORE I
for mounting the Flow Control Cube on top
Note:
The height of the temperature control unit increases by approx. 620 mm

The Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology.
The flow measurement is carried out with magnetically-inductive flow meters (MID) for electrically conductive liquids (e.g. water-glycol mixtures).
Temperature range: -40 ... 130 °C
Min. volume flow: 0,2 l/min
Max. volume flow: 80 l/min
Fluid connection: M38x1,5 male
Power supply: 90-240V 1~/2~ 50/60Hz

The Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology.
The flow measurement is carried out via a turbine flow meters (TURB) and can be calibrated for various liquids (e.g. silicone oils or water-glycol mixtures).
Temperature range: -90 ... 250 °C
with calibration: -30 ... 95 °C
Calibration (factory-set): Water-Ethylene Glycol 50:50
Min. volume flow: 0,9 l/min
Max. volume flow: 95 l/min
Fluid connection: M38x1,5 male
Power supply: 90-240V 1~/2~ 50/60Hz

The Multi Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology.
The flow measurement is carried out with magnetically-inductive flow meters (MID) for electrically conductive liquids (e.g. water-glycol mixtures).
In comparison to FCC, M-FCC has an independent controller, i.e. control takes place autonomously and communication with the Pilot ONE of the temperature control unit is not necessary. With M-FCC, multi-circuit control can be realised.
In most applications, a single temperature control unit is connected to an FCC for the first control loop. Additional M-FCC products are added for all further control loops.
Temperature range: -40 ... 130 °C
Min. volume flow: 0,2 l/min
Max. volume flow: 80 l/min
Fluid connection: M38x1,5 male
Power supply: 90-240V 1~/2~ 50/60Hz

The Multi Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology. The flow measurement is carried out via a turbine flow meters (TURB). The TURB flow meters can be calibrated for various liquids (e.g. silicone oils or water-glycol mixtures).
In comparison to FCC, M-FCC has an independent controller, i.e. control takes place autonomously and communication with the Pilot ONE of the temperature control unit is not necessary. With M-FCC, multi-circuit control can be realised.
In most applications, a single temperature control unit is connected to an FCC for the first control loop. Additional M-FCC products are added for all further control loops.
Temperature range: -90 ... 250 °C
Min. volume flow: 0,9 l/min
Max. volume flow: 95 l/min
Fluid connection: M38x1,5 male
Power supply: 90-240V 1~ 50/60Hz

The Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology.
The flow measurement is based on the Coriolis measuring method. An individual calibration for the liquid used is not necessary and can be used universally for different temperature control media.
Temperature range: -40 ... 150 °C
Min. volume flow: 0,2 l/min
Max. volume flow: 95 l/min
Fluid connection: M38x1,5 male
Power supply: 90-240V 1~/2~ 50/60Hz

The Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology.
The flow measurement is based on the Coriolis measuring method. An individual calibration for the liquid used is not necessary and can be used universally for different temperature control media.
Temperature range: -90 ... 240 °C
Min. volume flow: 0,9 l/min
Max. volume flow: 200 l/min
Fluid connection: flange DN32 PN10/40 EN1092-1
Power supply: 90-240V 1~/2~ 50/60Hz

The Multi Flow Control Cube is used to measure and control the flow and pressure of the thermal fluid. It can be used with Huber temperature control units with Pilot ONE technology.
The flow measurement is based on the Coriolis measuring method. An individual calibration for the liquid used is not necessary and can be used universally for different temperature control media.
In comparison to FCC, M-FCC has an independent controller, i.e. control takes place autonomously and communication with the Pilot ONE of the temperature control unit is not necessary. With M-FCC, multi-circuit control can be realised.
In most applications, a single temperature control unit is connected to an FCC for the first control loop. Additional M-FCC products are added for all further control loops.
Temperature range: -40 ... 150 °C
Min. volume flow: 0,9 l/min
Max. volume flow: 95 l/min
fluid connection: M38x1,5 male
Power supply: 90-240V 1~/2~ 50/60Hz

Mounting kit for FCC Flow Control Cube MID/TURB/CORE I
for mounting the Flow Control Cube on top
Note:
The height of the temperature control unit increases by approx. 620 mm

Temperature range: -20°C ... +140°C (max. 6 bar at +140°C)

HDPE with braiding
Temperature range: -20°C...90°C
Length: 300 cm
Connection: G1 1/4
Max. pressure at 20°C: 6 bar
Internal diameter: 32 mm


Temperature range: -10 ... +180°C (max. 6 bar at +180°C)
With universal mounting bracket for wall mounting of the manifold.
A hose of suitable length is required to connect between the manifold and the temperature control unit.

The following interfaces are integrated:
- Digital input: ECS
- Digital output: POKO
- Analogue interface:
- 1 input 4-20 mA / 0-10 V (switchable)
- 3 outputs 4-20 mA / 0-10 V (switchable)
- RS232 interface
- Up to three Com.G@te can be combined per temperature control unit, depending on the version of the temperature control unit
For units with Pilot ONE.

The following interfaces are integrated:
- Digital input: ECS
- Digital output: POKO
- Analogue interface:
- 1 input 4-20 mA / 0-10 V (switchable)
- 3 outputs 4-20 mA / 0-10 V (switchable)
- RS232 interface
- Up to three Com.G@tes can be combined per temperature control unit, depending on the version of the temperature control unit
For units with Pilot ONE.

The following interfaces are integrated:
- Digital input: ECS
- Digital output: POKO
- RS232 interface
- Up to three Com.G@te can be combined per temperature control unit, depending on the version of the temperature control unit
For units with Pilot ONE.

The international guarantee from Huber offers worldwide guarantee coverage for distributors, OEM partners etc.
Your advantages:
- Comprehensive care free package
- Professional repair work
- Fast execution of guarantee repairs
- Predictable guarantee costs
- Minimising downtime
- Simple handling of guarantee cases
- No further costs for repairs during guarantee

Electronic E-Grade-Package for extended
data communication with the following signals:
- Return temperature
- Power estimation
- PID-Parameter selection
- Compressor Automatic
- Digital communication of jacket and process temperature
- Reading of unit serial number
- Cooling water temperature and pressure
- Detailed parameter input prior to process start
- Feed forward control
- VPC control
- Flow control
- Availability of the variables device dependent

Consisting of:
- Atmosperic sealing kit
- Pressure regulator 20-200 mbar
- Safety valve 200 mbar opening
- Bubble counter
- Connection hose
- Max. pressure 1 bar
- Connection: G1/2
Unit not suitable for external installation.
Must not be installed in a closed room (room must be adequately ventilated).